The New AI Risk Management Standard: Familiar for Medical Devices, New Territory for Everyone Else
The draft prEN 18228 AI Risk Management Standard has been available for public comment over the past few weeks. We have analyzed the standard in detail and, in particular, explored the similarities and differences with the medical device risk management standard ISO 14971.
Our overall conclusion is straightforward: for medical device companies, prEN 18228 will feel remarkably familiar; for many other AI developers, it will represent an entirely new way of working.
The proposed standard introduces a structured and formal approach to AI risk management that closely resembles the processes that have been used in the medical device industry for decades. Organizations already working under ISO 14971 will recognize many of the concepts, requirements, and even the terminology. For them, implementing prEN 18228 is largely a matter of identifying and closing a limited number of gaps.
For many developers of high-risk AI systems outside the medical device domain, however, the challenge will be very different. While the standard is detailed and provides significant guidance, implementing a compliant risk management process requires more than writing a procedure. It requires organizations to define risk acceptability criteria, systematically identify and evaluate risks, document risk controls, and maintain risk management files throughout the lifecycle of the AI system. Companies without prior experience of a formal risk management framework will likely discover that this requires significant time, resources, and organizational maturity.
This matters because the timelines driven by the implementation of the AI Act leave relatively little time for organizations to prepare. Even though prEN 18228 is still in draft form, companies developing high-risk AI systems will need to start building their risk management capabilities long before the final version is published.
In this article, we share our observations from a detailed review of the draft standard. We discuss where prEN 18228 aligns closely with ISO 14971, where it introduces important new requirements, and what these differences mean in practice for organizations preparing for compliance with the AI Act.
Differences between prEN 18228 and ISO 14971
The general concepts and process are identical under both standards. The schematic representation of the risk management process in Figure 1 is nearly identical, with prEN 18228 only adding testing as a vertical block. Most of the defined terms, such as hazard, hazardous situation, and harm, are identical, since they are based on ISO/IEC Guide 63:2019, Guide to the development and inclusion of aspects of safety in International Standards for medical devices.

It is interesting to see that a number of concepts have been renamed. For example, under ISO 14971, top management is responsible for defining and documenting “a policy for establishing criteria for risk acceptability”. This is seen as providing the general framework for the types of inputs used and considerations taken into account when defining risk acceptability. This is defined at the organizational level and referenced in the risk management plan for individual products.
prEN 18228 classifies this as the risk management policy, which covers essentially the same concept. The one difference is that the standard currently appears less clear that this policy is not intended to be defined for individual AI systems, but rather at an organizational level across multiple products.
Another new term for an existing ISO 14971 concept is the use of risk scenarios, which appears to be identical to the concept of a “(foreseeable) sequence of events “. In ISO 14971, this is used to describe the different events or steps that can occur and turn a hazard into a hazardous situation. For example, “Electrode cable unintentionally plugged into power line receptacle” results in the hazardous situation “Line voltage appears on electrodes”. Based on the descriptions and figures provided in the draft prEN 18228, both concepts should be considered identical.
As discussed further below, using more generic terms such as risk management policy and risk scenariosfor concepts that already have a very specific meaning under ISO 14971 and now the prEN 18228 could create confusion for new users of these standards. For medical device companies, however, it is good news that these concepts and the overall process do not fundamentally change.
There are a number of areas where the new standard goes further and introduces additional requirements compared to ISO 14971. The AI Act explicitly requires the risk management process for high-risk systems to consider the potential impact on fundamental rights. As a result, prEN 18228 requires the formal evaluation of fundamental rights as part of the risk assessment process. Depending on the AI system, this may require explicit consideration of additional risks.
The potentially most impactful additional requirement is that risk acceptability criteria need to be based on “consultation with persons potentially affected, or their proxies, in particular vulnerable groups”. This goes beyond the typical requirements for medical devices, where in most cases the input of clinical experts (physicians) is considered sufficient.
The authors of the standard have requested additional input on potential alternative ways to ensure proper consideration of the effects on persons potentially affected. We will propose that medical ethics committees could provide an alternative mechanism to ensure proper consideration of the impact on patients. It will be interesting to see what other suggestions are provided and what the final wording of the standard will be in order to fully understand its ultimate impact.
It is also interesting that the standard defines the required level of risk reduction less strictly than the requirements for medical devices under the EU MDR. For medical devices, the EU MDR requires that all risks be reduced “as far as possible without negatively impacting the benefit-risk ratio”. In practice, this means that even for risks that are already deemed acceptable, companies still need to explore further risk reduction measures.
Under the AI risk management standard and the EU AI Act, this is not required. Risks that are deemed acceptable at the start of the process do not need to be considered further. For medical device companies, this means they will still need to continue reducing risks as far as possible in order to claim conformity with the EU MDR.
Challenges when implementing prEN 18228 as a first formal risk management process
For parties developing high-risk AI systems outside of the medical device domain, prEN 18228 may be the first formal risk management process they have had to implement. One of the challenges is that, although the standard is very detailed and provides guidance throughout, there is not yet a substantial body of technical reports or practical experience on how to implement it effectively.

For the medical device industry, ISO 14971 has been state of the art for nearly 30 years. The first edition was published in 1998 and the current third edition was published in 2019 and updated based on experience in the practice. Its implementation is supported by ISO/TR 24971, an excellent technical report that provides practical guidance on implementing the standard. It also offers additional background on several concepts that are equally important for this new AI risk management standard.
For example, the concepts of hazard, hazardous situation, and harmcan initially be difficult to grasp and often result in lengthy discussions within teams if everyone is not aligned. ISO/TR 24971 provides a useful overview and many practical examples that help explain these core concepts.
The prEN 18228 standard specifies that risks should be quantified based on both the probability and severity of the potential harm and that risk acceptability criteria need to be established. A common best practice is to use a matrix with probability on one axis and severity on the other. Although neither prEN 18228 nor ISO 14971 formally mandates the use of such matrices, prEN 18228 clearly suggests that their use may be expected, for example through the reference:
“If a risk chart or risk matrix is used for ranking risks for the purpose of estimating their severity and probability […]”
Again, ISO/TR 24971 provides useful insight into what is generally expected, including typical 3×3 or 5×5 matrices and guidance on probability ranges.
As indicated above, prEN 18228 defines a number of terms, such as risk management policy and risk scenarios, in a very narrow way that aligns with the more specific and prescriptive terminology used in ISO 14971. At present, however, prEN 18228 does not provide formal definitions for these concepts, which may encourage readers to look elsewhere for guidance.
This can lead to unintended confusion. For example, risk scenario in the new standard appears to cover only the concept of “the sequence of events that can lead to a hazardous situation”. In common usage and in other standards, however, the concept is often broader and includes the actual consequence (harm). For example, ISO 17666:2025 (Space systems – Programme management – Risk management) defines a risk scenario as a “sequence or combination of events leading from the initial cause to the unwanted consequence”. LLMs also tend to provide broader definitions and examples that include the harm. Similarly, risk management policyis often used almost synonymously with the entire risk management process.
Conclusion
The proposed prEN 18228 AI Risk Management Standard is clearly a descendant of ISO 14971, the long-established medical device risk management standard. For medical device companies that also develop AI systems, this is largely good news. Many of the underlying concepts, structures, and processes will already be familiar, and much of the required foundation is likely already in place.
Our review indicates that, for most medical device organizations, achieving alignment with prEN 18228 should primarily be a matter of identifying and closing a limited number of gaps. The most significant open question remains the potential requirement for consultation with affected persons. However, as this aspect is still being actively discussed by the authors of the standard, its final form remains uncertain.
For organizations outside the medical device domain, the challenge is likely to be greater. The draft standard introduces a level of rigor and formality that may be unfamiliar to many AI development teams. Building a compliant risk management process is not simply a documentation exercise. It requires organizations to establish governance, define risk acceptability criteria, perform structured risk analyses, and integrate risk management into the lifecycle of their AI systems. In our experience, this requires not only training but also close collaboration between compliance, quality, and technical teams to develop risk management files that are both practical and compliant.
As the AI Act implementation timelines continue to move forward, organizations will need to start building these capabilities well before the final version of the standard is published. Waiting for the final text may leave insufficient time to establish the necessary processes and organizational maturity.
At MD Squared, we have been following the development of the AI Act and its supporting standards closely. Based on the latest drafts, we have already performed detailed gap assessments against existing medical device standards and are developing practical methodologies, templates, and procedures to support implementation. Whether you are a medical device company seeking to align existing processes with the new requirements or an AI developer building a formal risk management framework for the first time, the key challenge is the same: translating the requirements of the standard into a process that works in practice.