When I start working with new medtech clients, I often see risk management files that look clean, compliant… and just a bit too generic.
Many teams use out-of-the-box templates for ISO 14971, and while there’s nothing wrong with a solid starting point, the problems start when those templates aren’t adapted to the actual device, use case, and clinical context.
📌 One common red flag?
Severity scales that look great on paper, but don’t reflect real-world impact.
The standard scale from ISO/TR 24971 (Table 4) is widely copied where the following categories are defined:
Results in…
💀 Catastrophic: …death
🧠 Critical: …permanent impairment or irreversible injury
🩺 Serious: …injury or impairment requiring medical or surgical intervention
🤕 Minor: …temporary injury or impairment not requiring medical or surgical intervention
😐 Negligible: …inconvenience or temporary discomfort
This is a solid starting point, but rarely a perfect fit.
Here’s why:
Let’s say your device is used during surgery. There might be harms, that the surgeon routinely corrects on the spot. No change in patient outcome. Yet, with this scale, such harms are to be classified as “Serious”, since they required surgical intervention.
That’s a misrepresentation of actual clinical risk, as also confirmed by clinical experts
💡 A better approach?
Refine the definition with clinical input. For example:
Serious: Results in injury or impairment requiring ADDITIONAL medical or surgical intervention.
Whatever scale you use, the key is this:
🔍 Always document the rationale behind each severity rating.
This supports consistency across the product lifecycle and avoids time-consuming debates during reviews (see one of my earlier posts on alignment of risks across the lifecycle).
🎯 Have you come across misaligned severity definitions?
📩 I’d love to hear how you adapted your scale, or what happened when you didn’t.
To comment and share your thoughts join the conversation at LinkedIn!
Related posts:

Public Gatekeepers, Private Returns
The commercial incentives shaping EU medical device conformity assessment Key Messages The EU’s decentralized conformity assessment model relies on independent, mostly commercial notified bodies to

When One QA/RA Hire Has to Be an Entire Department
When One QA/RA Hire Has to Be an Entire Department Why Quality and Regulatory work is fundamentally different in a medtech startup. Key messages A

Your Competitor Launches Faster. Their Notified Body May Be the Reason.
Your Competitor Launches Faster. Their Notified Body May Be the Reason. Why MedTech Leaders Should Benchmark Their Regulatory Strategy and Notified Body Performance Key messages: